Heart Plus AED

3,290.00 AED

Price Excluding of Vat

Product Highlights

Defibrillator

Defibrillator SeriesHeartPlus™ NT-180
Set ConfigurationDefibrillator, battery pack, sealed electrode pads, HeartPlus™ User Guide, Protective Carrying Case, “NT-MPR” CD-ROM USB cable
WaveformTruncated Exponential Biphasic
Energy180J (adult, impedance 50Ω) / 50J (pediatric, impedance 50Ω)
ShockChargelimeILess than 13 seconds
Shock MethodManual button (flashes when ready)
Mode ConversionAdult/Child separate power buttons Child Mode delivers 50J Pediatric shock for patients weighing less than 25kg, approximately 12 months to 8 years old)

Physical

Dimensions7.1cm (H) x29.3cm (W) x29.1cm (D)
Weight1.9kg (including battery pack and electrode pad)

Environmenta

Water resistanceIPX2 based on IEC 60529
TemperatureOperating : 0℃ to 40℃ / Storage : -20℃ to 60℃
Humidity
(operating/storage)
10% to 95% Relative Humidity, Non-Condensing
Altitude
(operating/storage)
0 to 2000 meters
Drop test1M

ECG

ECG RecordLEAD II
Analysis OverviewPatient evaluated to determine whether ECG rhythmrepresents shockable or non-shockable state. Shockable rhythms are ventricular fibrillation (VF) and ventricular tachycardia (VT).
Analysis timeLess than 11 seconds (Read: 5 seconds ± 2 seconds, Analyze: within 4 seconds)

Audio/ Visual instruction

After device is powered on, step-by-step voice instructions guide first responder through resuscitation procedure, which includes pads placement, hands offtimes (analysis and shock process), and CPR
CPR instruction prompts user to commence cardiopulmonary resuscitation, while flashing metronome light sets pace at 100 compressions per minute for 30 compressions with brief pause for 2 mouth-to-mouth breaths (5 repetitions), in accordance with American Heart Association 2010 guidelines.

Data

Storeda dataECG recordings, operation information (whether shock delivered or not), ambient noise, self-diagnostics history
Memory capacityECG: 1,000 instances of 5 seconds recordings Ambient
Noise: Total 60 minutes (4 instances of 15 minute cycles)
Self-Test: Times & results of 3,000 events
Storage typeInternal Memory
Access/search“NT-MPR” App (for PC) via USB connection

self-diagnostics Test

Daily self-diagnostics tests ensure that circuits for measuring patient impedance, control circuit internal discharge of electric energy, and control circuit for charge/discharge of electric energy are functioning
A voice prompt stating “Equipment check is needed” continuously in the event self-diagnostics check fails.
Upon completion of daily self-diagnostics test, results are automatically stored within device’s internal memory.

Battery Check

When battery reserve is at acceptable level to provide sufficient electric charges and there are no problems with circuitry detected during self check, there Status LEDs above the power button blink in order from left to right during self check.
All three Status LEDs blink at the same time continuously with low or critical battery voice prompts when battery is at low or critical levels (low: shock possible, critical: shock not possible).
Battery Status Audible WarningsLow: Voice prompt states “Battery’s voltage is low, check battery”
Critical: Voice prompt states “Change cartridge”

Electrode pads

Shelf LifeTwo (2) years, for one-time use only
Conductive GelPE foam, Hydrogel
Conductive ElementAgCl (Silver Chloride)
Cable Length2.1m (+1%)
Applicable AgesAll ages (12 months & older)
SealingAirtight
Size125mm x 95mm
Pads PlacementAnterior-lateral (visual details on pads)

Battery Cartridge

TypeNon-rechargeable lithium (LiMn02)
Capacity180 shocks @ 25℃ ,130 shocks @ 0℃
VoltageDC 21V& DC V / 1,400mAH
Standby Mode LifeRecommended five (5) years @ 25℃
Dimensions3.3cm (H) x 15.0cm (W) x 11.0cm (D)

23 in stock

Description

  • •Automated External Defibrillator
  • •Applied Technology- Biphasic waveform (BTE) Type
  • •Output Energy: Adult-180 Joules into a 50-ohm load; Infant/Child- 50 Joules into a 50-ohm load
  • •Operation mode: AED to analyze ventricular defibrillation
  • •Switching to Infant/Child mode: push-button
  • •Cartridge:
  • •Components: One time use electrode pad(Use for adults and infants), battery
  • •Structure: Air tight packaged cartridge with built-in pad and battery
  • •Dimensions: 150(w) x 110(l) x 33(h) mm
  • •Battery:
  • •Type: Non-rechargeable lithium battery
  • •Voltage: DC 21V (for energy charge)
  • DC 9V (for inner circuit control)
  • •Alarms and Voice Prompts
  • •Voice prompts regarding entire process
  • •Detailed voice prompts about electric shocks and CPR
  • •Voice prompts for self-diagnosis results
  • •Storage and management of data and events
  • •Storage content: electrocardiograms, number of shocks, ambient noise during use, time for self-diagnosis and results, total days of use
  • •Storage period:1000 events storage(ECG). Maximum 15 minutes for ambient noise. Maximum 3000 self diagnosis results
  • •Data communication: Either USB or Bluetooth
  • •Data storage: supports both internal memory and external SD-Memory

 

Scope Of Supply:

  • • HeartPlus AED x 1
  • •Adult/pead pad x 1
  • •Battery x 1
  • •Bag x 1

Warranty:
Standard warranty period is Five (5) years from the date of delivery. All warranty are valid only againts manufacturing defect, excluding wear and tear parts, accident, abuse and failure to follow instruction manual.

Additional information

Weight2 kg
Country of Origin

South korea

Reviews

There are no reviews yet.

Be the first to review “Heart Plus AED”